Purge and Pressurization

With Pepperl+Fuchs’ Bebco EPS purging and pressurization, you get:

  • State-of-the-art solutions based on more than 20 years of experience – a family of automatic purge and pressurization systems that make hazardous location protection easy
  • Purge and pressurization systems designed according to ATEX direction 94/9/EG, NFPA 496, and ISA 12.4 standards
  • Easy integration – compact, low-profile designs that can be internally or externally mounted
  • Automatic temperature and leakage control and alarming
  • User interface with programming to meet most users’ demands
  • Pepperl+Fuchs offers a full range of purge and pressurization equipment to meet the needs of your application. Another benefit of purging and pressurization is use of the standard Type 4/12 enclosure as the protected enclosure. This saves money, weight, and space over other  explosion-proof methods.

View the Purge & Pressurization Product Comparison Table

Pepperl+Fuchs Purge & Pressurization Product Overview

Pepperl+Fuchs Purge Pressurization Systems Type X Purge

Type X

  • Type X purge systems reduce the classification within the protected enclosures from Division 1 to non-hazardous. General-purpose equipment can be operated within the protected enclosure.
  • Note: Vents are required for most purge enclosures
  • The Pepperl+Fuchs Type X purge system is fully automatic and performs critical purging, pressurization and monitoring of the protected enclosure. It is designed according to NFPA 496 and ISA 12.4 standards.
Pepperl+Fuchs Purge Pressurization Systems Type Y Purge

Type Y

  • Type Y purging systems  reduce the classification within the protected enclosure from Division 1 to Division 2. All equipment used within the enclosure must be Division 2 rated.
  • Note: Vents are required for most Type Y purge enclosures
  • The Type Y purge system:
    • Allows Division 2 rated equipment to be operated in a Division 1 location
    • Controls purging, pressurization & monitoring pressures
    • Rated for Class I/ II, Division 1 to Division 2 area applications
    • Purge enclosure sizes to 450 cu. ft.
    • UL, cUL, FM classifications
    • Conforms to NFPA 496 and ISA 12.4 standards
Pepperl+Fuchs Purge Pressurization Systems Type Z Purge

Type Z

  • Type Z / Ex pz purge and pressurization systems provide easy selection, installation, and operation for enclosures located in Division 2 / Zone 2 hazardous areas.  The Type Z / Ex pz solutions consist of a control unit, vent, and solenoid valves. The combination of automation and configurable functions support even the most difficult applications.
  • Automatic systems for alarm, purging, and power to the enclosure
  • Enclosure sizes to 450 cu. ft.
  • Conforms to NFPA 496 and ISA 12.4 standards
  • ATEX, IECEx, and UL certified systems
  • Built-in programming (programmable temperature control / leakage compensation)
Pepperl+Fuchs Purge Pressurization Systems Type Ex/pxb Purge

Ex Px

  • Ex px purge systems  reduce the classification within the protected enclosure from Zone 1/ Zone 21 to non-hazardous. General-purpose equipment can be operated within the protected enclosure.
  • Note: Vents are required for all purge enclosures.
  • Designed according to European requirements- ATEX directive 94/9/EG, EN60079-2 and EN61241-4. European protection methods allow multiple techniques to be used when designing hazardous area equipment.
Pepperl+Fuchs Purge Pressurization Systems Type Z/Ex pzb Purge

Ex Pz

  • EPS Ex pz purge and pressurization systems provide easy selection, installation, and operation for enclosures located in Zone 2 and 22 hazardous areas. The Ex pz solutions consist of a control unit, vent, and solenoid valves. The combination of automation and configurable functions support even the most difficult applications.
  • Automatic systems for alarm, purging, and power to enclosure
  • Enclosure sizes to 450 cu. ft.
  • Conforms to NFPA 496 and ISA 12.4 standards
  • ATEX, IECEx, and UL certified systems
  • Built-in programming (programmable temperature control/ leakage compensation)
Pepperl+Fuchs Purge Pressurization Systems Enviro-Line Pressurization

Enviro-Line Pressurization Systems

  • Enviro-Line purging units is an enclosure pressurization system for non hazardous areas that operates on a supply of compressed instrument air or inert gas. It regulates and monitors the pressure within the sealed enclosure at a constant pressure in order to prevent the accumulation of damaging and caustic gases and dusts.
  • The elimination of these gases and dusts extends the life of expensive electrical equipment and instrumentation placed within the Enviro-Line purging unit.
  • Due to higher pressures inside the electrical enclosure, corrosive environments remain outside. The system maintains a constant 0.5″ water pressure inside the enclosure for protection against gas and/or dust.